mohanchen
left a comment
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
LGTM
|
Two self-consistent DFT calculations were performed for a FM and an AFM configuration of a two-iron-atom system using a single Γ-centered k-point (1×1×1), a kinetic energy cutoff of 80 Ry, a gaussian smearing of 0.015Ry, and an SCF convergence threshold of 1e-7. The first calculation was carried out with Quantum ESPRESSO (QE), and the second with ABACUS. (Same atomic configuration as the provided tests with different energy cutoffs and convergence threshold. ) FM
AFM
|

Last fix corrected the index for occupational number, but made that of wavefunction wrong. By introducing a unified parameter
iq_loc_spin, this PR should fix spin-polarized EXX PW calculations.Note that this PR doesn't seem to fix issue #6841. I've tested the cases provided in that issue with a smaller set of k-points, still gives a FM phase for cerium.